ISAIND HF – High-frequency X-ray generators
Precise power for every X-ray room. The ISAIND HF series brings together five high-frequency generators from 40 to 150 kV and up to 800 mA, ready for new rooms and for upgrading analog rooms to digital radiography (DR). They integrate with your tube, your bucky and your flat panel detector, and are calibrated from software.

No published price and no online checkout. Configuration and availability are confirmed when quoting.
Key figures
- 40–150 kV · kV range
- ≤1 ms · kV rise @ 100 kV
- 10–800 mA · Tube current
- 32–56 kW · Nominal power · up to 70 kW
Models
- HF-32S · single phase 220 VAC · 32 / 40 kW
- HF-40S · single phase 220 VAC · 40 / 50 kW
- HF-40T · three phase 380 VAC · 40 / 50 kW
- HF-50T · three phase 380 VAC · 50 / 63 kW
- HF-56T · three phase 380/400 VAC · 56 / 70 kW
Downloads
WhatsApp +593 98 998 5755 · Jardines del Salado Mz 207 V15, Guayaquil, Ecuador · info@isaind.com · isaind.com
Accurate exposures, simple integration and a generator built to last
Ready for DR retrofit
Flat panel detector sync interlock, Bucky Start/Ready signals and a communication protocol for imaging software: convert analog rooms to digital without replacing the whole room.
Works with your tube
Compatible with single-phase, three-phase, low-speed, high-speed and dual-speed tubes. Dual-speed automatic rotor control with variable-frequency drive.
kV and mA precision
kV ±5% @ ≥100 kV, tube current ±(5% + 1 mA) and mAs ±(5% + 0.2 mAs) @ ≥10 ms. Built-in tube curves and automatic filament calibration.
Fast response
kV rise ≤1 ms @ 100 kV and exposures from 1 to 10,000 ms, driven by a fast-response high-voltage inverter control algorithm.
Rugged high-voltage tank
Monolithic die-cast tank, vacuum oil filling and high insulation level: withstands 240 kV. Five-stage EMC filtering.
Easy integration and calibration
Mini or full console plus configuration software: filament calibration, profile import, log export and interface status setup.
ISAIND HF + ISAIND Fluoro bundle
ISAIND HF generators are also offered as a bundle together with ISAIND Fluoro, our imaging software: generator and software from a single supplier, with unified integration and support. The scope of each bundle is defined with ISAIND for your project; configuration and compatibility are confirmed on site, with no universal compatibility declared.
A single supplier
The X-ray generator and the ISAIND Fluoro software come from the same company, with one point of contact for your project.
Unified integration
ISAIND coordinates the integration of the generator and the software with your system and verifies the configuration on site.
Unified support
Technical support, training and maintenance handled by the same team, directly via WhatsApp and email.
Gallery






Who is the ISAIND HF series for?
Integrators & manufacturers
A generator with standard interfaces to equip conventional and DR rooms with your own table, bucky and detector.
Retrofit workshops
Replace aging generators and move analog rooms to digital with flat panel detector synchronization.
Distributors
Five single- and three-phase models to cover everything from clinics to hospitals.
Hospitals & clinics
Renew your room’s generator and gain precision and repeatability in every exposure.
Technical specifications
By model
| Model | HF-32S | HF-40S | HF-40T | HF-50T | HF-56T |
|---|---|---|---|---|---|
| Phase | Single phase | Single phase | Three phase | Three phase | Three phase |
| Input voltage | 220 VAC · 50/60 Hz | 220 VAC · 50/60 Hz | 380 VAC · 50/60 Hz | 380 VAC · 50/60 Hz | 380/400 VAC · 50/60 Hz |
| Nominal / maximum power | 32 kW / 40 kW | 40 kW / 50 kW | 40 kW / 50 kW | 50 kW / 63 kW | 56 kW / 70 kW |
| Tube current range | 10–400 mA | 10–500 mA | 10–500 mA | 10–630 mA | 10–800 mA |
| mAs range | 0.1–400 mAs | 0.1–400 mAs | 0.1–1000 mAs | 0.1–1000 mAs | 0.1–1000 mAs |
| Weight | 110 kg | 110 kg | 78 kg | 78 kg | 78 kg |
Common to all models
| kV range | 40–150 kV |
|---|---|
| kV accuracy | ±5% @ ≥100 kV · 4 kV @ <100 kV |
| kV rise time | ≤1 ms @ 100 kV (10%–90%) |
| Tube current accuracy | ±(5% + 1 mA) @ ≥10 ms · ±(20% + 1 mA) @ <10 ms |
| mAs accuracy | ±(5% + 0.2 mAs) @ ≥10 ms · ±(10% + 0.2 mAs) @ <10 ms |
| Exposure time | 1–10,000 ms |
| Exposure time accuracy | ±(2% + 0.5 ms) @ ≥10 ms · ±(5% + 1 ms) @ <10 ms |
| Rotor control | Dual-speed automatic control |
| Optional | AEC / DAP |
| Dimensions | 700 × 400 × 680 mm |
| High-voltage tank | Monolithic die-cast, vacuum oil filling, 240 kV withstand voltage |
Interfaces
| Room light | Relay-type output signal for indicator light |
|---|---|
| Bucky Start | Output signal for X-ray exposure synchronization |
| Bucky Ready | Input signal for X-ray exposure synchronization |
| Tube thermal switch | Input signal for X-ray tube thermal switch |
| Interlock | Input for flat panel detector exposure synchronization |
| Door interlock | Input detecting the status of the shielded lead door |
| Bucky supply | 24 VDC / 110 VAC / 220 VAC output to Bucky |
| Collimator supply | 24 V output to the collimator |
| AEC | Ionization chamber connection for automatic exposure control |
| DAP | Software-based dose area product calculation |
| Emergency stop | External emergency stop button connection |
| Communication protocol | Communication with imaging software and custom protocol |
| X-ray tube | Compatible with single-phase, three-phase, low-speed, high-speed and dual-speed tubes |
Specifications subject to change without notice; please confirm the configuration with ISAIND before purchase. Images for reference only. Import and registration requirements vary by country.
A technical partner for your project
ISAIND specializes in medical imaging: we refurbish, remanufacture, recondition and maintain X-ray equipment and C-arms. With the ISAIND HF series we help you choose the model, integrate it into your room and support you for its entire service life.
Choosing the model
Tell us your tube, your mains supply (220 or 380/400 VAC) and your detector, and we will recommend the right model.
Installation and calibration
Setup, filament calibration and functional testing with your equipment.
Technical support
Engineers who know the system in depth, with direct support via WhatsApp and email.
Remanufacturing experience
Real knowledge of generators, tubes and detectors from our refabrication and reconditioning work.
Request the full datasheet and a proposal for your project
For integrators, retrofit workshops, distributors and hospitals worldwide. Tell us what you need and we will reply with clear technical information and no commitment.
Technical service and parts
For this equipment you can also request technical service or quote parts.